Architectural Lighting Glossary

Twenty terms that decide whether a facade lighting configuration is quoted correctly. Each entry gives the definition first, then the practical consequence.

Why a glossary

Most project disputes trace back to a term used with two meanings — an IP rating read as unlimited exposure, DMX512 assumed to mean universal compatibility, or a beam angle chosen without setback. These definitions state what each term means and what it does not mean.

Jump to: B · C · D · G · I · M · N · O · P · R · S · U · V · W

B

Beam Angle

The angular width of the light distribution emitted by a fixture, usually measured between points where intensity falls to half of the peak.

A narrow beam concentrates intensity and creates hotspots at short distance; a wide beam covers more area but loses intensity at long throw. Beam choice is a function of mounting distance and target size, not a standalone quality parameter.

Read the full article

C

Colour Temperature (CCT)

The correlated colour temperature of a light source in kelvin, describing whether the white light appears warm or cool relative to a reference.

A 3000 K and a 4000 K fixture beside each other are visible as different whites even if both are called warm white. For facades with several fixture families, one approved sample defines the target CCT and batches are checked against it.

Read the full article

CRI (Colour Rendering Index)

A measure of how faithfully a light source reveals the colours of objects compared with a reference source, expressed on a 0–100 scale.

CRI matters where material colour must read correctly, such as stone, masonry or signage. It does not describe fixture efficiency or brightness, and a high CRI usually reduces output for the same power.

Read the full article

D

DMX512 — Digital Multiplex 512

A digital control protocol for lighting in which each fixture or segment is assigned an address and receives brightness or colour values from a controller over a differential serial link.

A DMX512 universe carries 512 control channels. An RGB fixture using three channels occupies three addresses, so one universe can address roughly 170 simple RGB fixtures before a second universe is needed. Compatibility depends on channel mode, wire sequence and controller behaviour, not on the protocol name alone.

Read the full article

G

Grazing

A lighting technique in which light strikes a surface at a shallow angle so surface relief and texture become visible through contrast.

Grazing exaggerates texture and also exaggerates imperfections. It needs close setback and careful beam control; on a smooth glass facade it usually reveals nothing useful and even washing is the better choice.

Read the full article

Glare

Excessive or uncontrolled brightness in the field of view that reduces visual comfort or obscures detail.

On facades, glare is usually caused by exposed LEDs aimed toward observers or drivers. It is controlled by mounting position, aiming, beam choice and shielding; it is not solved by increasing or reducing total power alone.

Read the full article

I

IP Rating (Ingress Protection)

A two-digit classification from IEC 60529 describing protection against solid objects and water, where the second digit refers to water exposure.

IP65 means dust protected and protected against water jets; IP67 adds temporary immersion under defined conditions; IP68 is defined by the manufacturer’s stated test. An IP number never guarantees performance where connectors, seals or installation are wrong, and IP68 does not mean permanent submersion.

Read the full article

Inground Light

A luminaire installed into a recess in the ground so its lens sits close to the finished surface, typically used for uplighting.

Performance depends on drainage, load class and cable routing as much as on optical output. An IP marking does not replace a drainage layer, and a recessed fixture that cannot be serviced becomes a maintenance problem.

Read the full article

Incoterm

An internationally agreed trade term that defines which party pays for transport, insurance, export clearance and delivery risk.

A quotation is incomplete without an Incoterm and a named place. GDXC quotes EXW, FOB Shenzhen or DAP where agreed; the term changes the landed cost and the point at which risk transfers.

Read the full article

M

MOQ (Minimum Order Quantity)

The smallest quantity a supplier will accept for a production order of a given item or configuration.

MOQ depends on model, component purchasing and any customisation. GDXC does not publish a universal MOQ because a standard pixel and a custom-labelled linear run have different production conditions.

Read the full article

N

Neon Flex

A flexible linear luminaire in which LEDs are mounted on a bendable board inside a diffused sleeve, used for curves and continuous outlines.

Bending direction, minimum radius, end treatment and supply points are model-specific. A strip bent on the wrong axis fails at the first corner, so the curve drawing is required before a product is proposed.

Read the full article

O

OEM / ODM

OEM supplies a product under a buyer’s brand; ODM adapts an existing product design or configuration to a buyer’s specification.

Both require an agreed scope covering structure changes, labels, documentation, quantity and schedule. GDXC confirms these per approved order and does not publish a single MOQ or a blanket exclusivity promise.

Read the full article

P

Pixel Mapping

The process of assigning each physical LED point in an installation to a coordinate in the content source so an image or animation appears correctly across the facade.

A roof using 42,000 pixel points needs a map that follows the physical layout, not a rectangular assumption. A wrong map produces mirrored or broken images even when every fixture works; GDXC reviews point layout against the drawing before supply.

Read the full article

Power Injection

The practice of connecting the supply at additional points along a low-voltage LED run to keep voltage within the operating range at every fixture.

Injection points are decided together with cable sizing and fixture power. For pixel runs, the position of injection affects colour consistency as much as brightness, so it is planned before installation rather than added after a dim section is observed.

Read the full article

R

RGB / RGBW

LED configurations using red, green and blue emitters, or those three plus a separate white emitter, to produce colour and white light.

RGB mixes white from coloured emitters and may show colour shift at low brightness; RGBW has a dedicated white channel for cleaner white and higher efficiency. Channel count changes DMX addressing, so it must be fixed in the configuration sheet.

Read the full article

S

Setback Distance

The distance between the front of a luminaire and the surface it is intended to light.

Setback changes both coverage and the character of the light. A short setback creates grazing texture; a longer setback spreads the beam and reduces brightness. It is one of the first inputs GDXC requests for a wall-washing enquiry.

Read the full article

Sample Section

A short, powered assembly of the proposed fixtures used to check brightness, colour and control behaviour before a full order.

A sample section validates the configuration under agreed conditions. It cannot prove the final building appearance, which also depends on wall finish, viewing position and the rest of the lighting scheme.

Read the full article

U

Uniformity

The variation in illuminance or luminance across a lit surface, usually expressed as a ratio between minimum and average or maximum values.

Uniform washing depends on spacing, beam overlap, setback and reflectance. Dark bands are normally a layout problem before they are a fixture problem, which is why GDXC asks for the wall drawing before recommending a product.

Read the full article

V

Voltage Drop

The reduction in voltage along a cable caused by its resistance and the current flowing through it, which increases with run length.

On long low-voltage LED runs, voltage drop makes the far end dimmer and can cause colour shifts. It is calculated from current, cable cross-section and length; supply injection points are placed accordingly. Fixture count alone does not define the maximum run.

Read the full article

W

Wall Washer

A linear luminaire with an asymmetric or narrow beam designed to spread light across a vertical surface to reveal texture or produce even illumination.

Result depends on setback distance, beam angle, spacing and wall reflectance. The same fixture at 300 mm and 1,200 mm offset can produce grazing texture or even washing. GDXC lists 30°, 60°, 10×30° and 10×60° beam options on the GD-WW3524 platform.

Read the full article

IP ratings follow IEC 60529; DMX512 follows the ANSI E1.11 standard. Where industry usage differs from the standard, the practical consequence is noted in the detail paragraph.

Send drawings, get a quote in 24 hours

Upload a STEP file and a drawing. You will receive a fixed-price quotation with lead time and a written DFM report — no obligation, and no sales call unless you ask for one.

Chat on WhatsApp