DMX512 Control Coordination for Architectural Lighting
GDXC reviews controller interfaces, channel modes, wire sequence, address maps and power for pixel, linear and wall-washer configurations before supply.
DMX512 is a digital control protocol that sends address-based commands to lighting fixtures, allowing each fixture or segment to change brightness and colour independently. GDXC reviews controller model, channel mode, wire sequence, address map and supply topology for pixel, linear and wall-washer projects, and confirms compatibility against the exact fixture configuration rather than a brand name.
When this process applies
This capability covers control review, address planning and interface documentation for the fixtures we supply. It does not include site programming, control-cabinet manufacture or responsibility for third-party control equipment; those roles are defined in the project scope sheet.
Technical specifications
| Protocol | DMX512 (legacy MDX512 spelling corrected) |
|---|---|
| Review inputs | Controller model, channel mode, wire sequence, address map |
| Fixture families | Pixel, linear, wall washer, flood |
| Deliverable | Interface and address-plan documentation |
| Sample validation | Section test with the project controller |
| Scope boundary | Site programming and control cabinets excluded |
Where it is the right choice
- Pixel-mapped media facades and roof canvases
- RGB and RGBW linear runs with chasing effects
- Retrofits into an existing DMX512 installation
- Projects where multiple fixture families share one controller
Where it is the wrong choice
Stating this explicitly matters more than a capability list: if your part falls into one of these categories, another process will cost you less.
- Projects requiring GDXC to program or commission the site controller
- Control systems using a non-DMX protocol without an agreed gateway
- Claims of universal compatibility based only on a controller brand name
Equipment
- DMX512 test controller
- Addressing and mapping tools
- Sample pixel and linear sections
- Power and voltage-drop calculation sheets
Process questions
Will your fixtures work with my DMX512 controller?
We confirm against the exact model: controller, channel mode, wire sequence, IC and address map. A controller brand alone is not enough to guarantee compatibility.
Do you program the lighting show?
Control programming and site commissioning are defined separately in the project scope. We supply fixture documentation and a reviewed address plan.
Can old MDX512 catalogue text be trusted?
No. The legacy MDX512 spelling in the point-light catalogue was a typo and is now written DMX512. Actual interface behaviour still requires verification.
Related capabilities and products
Send drawings, get a quote in 24 hours
Upload a STEP file and a drawing. You will receive a fixed-price quotation with lead time and a written DFM report — no obligation, and no sales call unless you ask for one.